Home | Forums | Telephony | Files | Docs | Communities | Contact | About
How to Login to Meridian 1/CS1000 | How to Setup an Analog Central Office Trunk | NTAK04AA Capacitor Replacement

Nortel NTAK04AA RLSE 17 Capacitor Replacement

HIGH-VOLTAGE SAFETY WARNING

The NTAK04AA is a mains-powered power supply and contains potentially lethal voltages. Dangerous voltages may remain present inside the unit even after it has been disconnected from AC power, particularly around the high-voltage section and large capacitors.

Do not open, service, or attempt to repair this power supply unless you are properly qualified and understand the hazards associated with mains-powered equipment.

Appropriate electrical safety procedures and test equipment should be used throughout any repair. If you are not experienced with this type of equipment, do not attempt the repair yourself.

Repair Scope Disclaimer

This document describes my personal repair and restoration of a Nortel NTAK04AA power supply. It is not an official Nortel repair procedure, service manual, or manufacturer-approved refurbishment guide.

Component selections, measurements, procedures, and conclusions documented here are based on my particular unit and may not apply to every NTAK04AA or every hardware revision.

Some information may be incomplete or incorrect, especially while this project is still in progress.

This guide is provided for documentation and educational purposes only.


Introduction

The NTAK04AA from Nortel is an AC/DC power supply used to power the Option 11/11C and CS1000E systems. There is a more modern variant, the NTDK78, but at the time of writing, these are being sold from Israel for around $250, making repair of an existing NTAK04AA a much more appealing option.

My NTAK04AA had begun suffering from noticeable coil whine along with what I can only describe as a "cooking food" smell coming from the power supply. This is commonly associated with aging, end-of-life capacitors, particularly when electrolytic capacitors begin to deteriorate and leak or otherwise fail.

My particular unit was manufactured in 1996 and has been in service for nearly 30 years. Rather than replacing it with a much newer and significantly more expensive power supply, I'm going to put the work into restoring this unit properly.

The goal is to replace the aging components, address the issues that have developed over the years, and hopefully give this nearly 30-year-old power supply another 30 years of service.


Disassembly

Step 1 - Remove the Front Cover

There are two clips located on the very top and bottom of the unit that secure the front plastic cover to the power supply chassis.

Carefully release these clips and remove the front plastic cover from the chassis.

Once the cover has been removed, you will find four screws securing the circuit breaker assembly. These four screws need to be removed to continue disassembly.

PHOTO PLACEHOLDER: Front cover clips and circuit breaker screw locations.

Step 2 - Remove the AC Board

With the front cover and circuit-breaker mounting screws removed, lay the unit down on the DC side. This will position the rear side of the AC board facing upward.

Once the unit is positioned correctly, remove the 12 screws securing the AC board to the chassis.

PHOTO PLACEHOLDER: Correct unit orientation and locations of all 12 AC board mounting screws.